7-10
Maintenance of laser
B337EN07.doc
Filling volumes and
conductivity
Copper cooling
circuit
KK1 Cu
Aluminium cooling
circuit
KK2 Al
Tank volumes
55 (65)* l
320 (450)* l
Total water volumes
85 (95)* l
350 (480)* l
Conductivity for freshly
filled water
max. 10 µS/cm
max. 10 µS/cm
Conductivity limit
with all additives
200 µS/cm
200 µS/cm
Signs indicating volume amounts are also located on the
respective water tank at the laser unit’s cooling unit.
Cooling water additives
KK1 Cu
cooling circuit
KK2 Al
cooling circuit
Corrosion protection
NALCO 2513
NALCO 2513
Supplied volume
125 ml
125 ml
Volume when filling up
cooling water
5 ml /
100 l water
5 ml /
100 l water
Volume at
completed
cooling water change
4 (5)* ml
18 (24)* ml
Mat. no.
0344669
0344669
Protection against
bacteria and algae
NALCO 2594
NALCO 2594
Supplied volume
125 ml
125 ml
Volume when filling up
cooling water
5 ml /
100 l water
5 ml /
100 l water
Volume at
completed
cooling water change
4 (5)* ml
18 (24)* ml
Mat. no.
0344670
0344670
Additive for cleaning
cycle
ST-40
(ST-30)
ST-40
(ST-30)
Amount required
for cleaning cycle
15 ml /
100 l water
15 ml /
100 l water
Mat.-Nr.
0344899
0344899
* Cooling unit for TLF5000
Caution!
Cooling water additives have a caustic effect on skin and eyes.
Wear safety glasses and safety gloves when working with cooling
water additives. Observe information on products and product
packaging.
* Cooling unit for TLF5000
Содержание LASERCELL 1005
Страница 1: ...Operator s manual TRUMPF LASERCELL 1005...
Страница 2: ......
Страница 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Страница 6: ...0 6 Before You proceed B337EN00 DOC...
Страница 22: ...0 22 Table of Contents B337EN00 DOC...
Страница 23: ...1...
Страница 61: ...1 38 Laser processing B337EN01 DOC...
Страница 62: ...2...
Страница 107: ...3...
Страница 160: ...4...
Страница 238: ...4 78 Operation B337EN4_3 Fig 39422 Fig 39423en Cutting a large contour Cutting a medium contour...
Страница 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Страница 409: ...B337EN4_8 Operation 4 249 Fig 36626 Fig 36627 Backup starts 6 Enter file name press Enter 7 Press Y...
Страница 412: ...4 252 Operation B337EN4_8...
Страница 413: ...5...
Страница 515: ...5 102 Further service programs B337EN05 DOC...
Страница 516: ...6...
Страница 546: ...6 30 Machine maintenance B337EN06 doc 5 Maintenance of pneumatic components and filters 5 1 Instrument panel Fig 39484...
Страница 589: ...7...
Страница 628: ...8...
Страница 635: ...B337EN08 DOC Cross hairs to cut out 8 7 5 Cross hairs to cut out Cross hairs to cut out Fig 6310...
Страница 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Страница 637: ...9...
Страница 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Страница 644: ...10...