B337EN02.DOC
Installation conditions TLC 1000 and TLC 1005 - Version 5
2-25
3.2 Connected
loads, fuse protection
The following data represents standard values, which may vary
depending on the machine equipment:
Connected loads of the machine
with laser
TLF
2000
TLF
2700
TLF
3200
TLF
4000
TLF
5000
TLF
6000
TLF
8000t
TLF
12000t
Total connected load incl. all possible
options and cooling unit
[kVA] 64
75
78
98
161
171
228
336
Maximum fuse protection of the
complete system
at 400 V
[A]
at 460 V
[A]
100
100
125
100
125
100
160
125
200
200
250
200
315
250
400
400
Total connected load incl. all possible
options without cooling unit
[kVA] 46
54
57
72
117
127
163
263
Max. fuse protection of the complete
system without cooling unit
at 400 V
[A]
at 460 V
[A]
80
63
80
80
100
80
100
100
125
125
160
125
160
160
315
250
Connected loads of the cooling unit
[kVA] 18
21
21
26
44
44
65
73
Fuse protection, cooling unit
at 400 V
[A] 50
50
50
50
63
63
100
160
Cross-section power cable complete
system
[mm
2
] 35
50
50
70
95
120
185
240
Maximum acceptable interruption of
nominal voltage
[ms]
See EN 60204, Part 1, Point 4.3.2, Alternating current supply.
Connected loads, fuse protection
The following applies to cooling units that are equipped with a tank
heating, e.g.: when installed outdoors:
•
The cooling unit is switched on and off using a separate main
switch and requires a separate mains connection to be
provided by the customer.
•
The connected load of the complete system can be reduced by
the connected load of the cooling unit.
•
The power cable is laid after delivery. It can be fed over the
cooling unit pedestal.
Table 2-19
Cooling unit with tank
heating (optional)
Содержание LASERCELL 1005
Страница 1: ...Operator s manual TRUMPF LASERCELL 1005...
Страница 2: ......
Страница 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Страница 6: ...0 6 Before You proceed B337EN00 DOC...
Страница 22: ...0 22 Table of Contents B337EN00 DOC...
Страница 23: ...1...
Страница 61: ...1 38 Laser processing B337EN01 DOC...
Страница 62: ...2...
Страница 107: ...3...
Страница 160: ...4...
Страница 238: ...4 78 Operation B337EN4_3 Fig 39422 Fig 39423en Cutting a large contour Cutting a medium contour...
Страница 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Страница 409: ...B337EN4_8 Operation 4 249 Fig 36626 Fig 36627 Backup starts 6 Enter file name press Enter 7 Press Y...
Страница 412: ...4 252 Operation B337EN4_8...
Страница 413: ...5...
Страница 515: ...5 102 Further service programs B337EN05 DOC...
Страница 516: ...6...
Страница 546: ...6 30 Machine maintenance B337EN06 doc 5 Maintenance of pneumatic components and filters 5 1 Instrument panel Fig 39484...
Страница 589: ...7...
Страница 628: ...8...
Страница 635: ...B337EN08 DOC Cross hairs to cut out 8 7 5 Cross hairs to cut out Cross hairs to cut out Fig 6310...
Страница 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Страница 637: ...9...
Страница 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Страница 644: ...10...