1.8
Remove the bolt Figure 1 [9] and washer Figure 1 [8].
1.9
Remove the LDR Figure 1 [4] from the aircraft.
2
Installation
2.1
Make sure that the ESD wrist strap (Pt.No. Local supply) is securely connected to a good ground point
on the LDR.
2.2
Put the LDR Figure 1 [4] in position in the battery bay.
2.3
Install the bolt Figure 1 [9] and washer Figure 1 [8].
2.4
Install the two bolts Figure 1 [2] and washers Figure 1 [3].
2.5
Safety the two bolts Figure 1 [2] with Lockwire (Pt.No. P02-022) Figure 1 [1].
2.6
Connect the DB 50 connector Figure 1 [5] to the LDR Figure 1 [4].
2.7
Hand tighten the two DB 50 connector screws Figure 1 [6].
2.8
On the CVFDR Panel in the battery bay, remove the safety clip and close the following circuit breaker:
−
CVFDR POWER.
3
Close Up
3.1
Do an operational test of the LDR, refer to AMM 12-B-31-30-01-00A-903A-A .
3.2
Remove all the equipment, tools and materials from the work area. Make sure that the work area is
clean.
3.3
Close the access panel 31AB.
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-31-30-01-00A-920A-A
UNCLASSIFIED
2021-12-04 Page 3