Table 2 Master Maintenance Plan Task List (Continued from previous page)
Task number
Item Name
Task Description
Interval
Data Module Refer-
ence
29-10/257
Power pack (If instal-
led)
Examine, specially
for leaks and cracks
on the end plates
and where motor is
attached
1,200 FH / 12 Months 12-B-29-00-00-00A-
902A-A
29-10/258
Nitrogen accumulator
(P/N 960.30.01.291)
(If installed)
Check nitrogen pres-
sure and fill as nec-
essary
1,200 FH / 12 Months 12-B-29-10-02-00A-
901A-A
29-10/259
Power pack electric
motor shaft seal drain
fluid collector bottle
(If installed). (Post
SB 29–002 and MSN
1001-9999)
Remove, clean and
reinstall
1,200 FH / 12 Months -
29-10/316
Hydraulic system (If
installed)
Make sure fluid level
indicator on the res-
ervoir tank shows full.
Fill as needed.
300 FH / 12 Months
12-B-29-00-00-00A-
902A-A
*29-10/418
Nitrogen accumulator Life limit
25,000 FH /
30,000 LDG
-
29-10/471
Nitrogen accumulator
(P/N 960.30.01.292)
(If installed)
Check nitrogen pres-
sure and fill as nec-
essary
2,400 FH / 24 Months 12-B-29-10-02-00A-
901A-A
30-10/79
Airfoil de-icers
Apply a surface coat-
ing of Age Master
No. 1 in accordance
with the manufactur-
ers instructions CMM
30-10-31 (latest is-
sue)
Note
The deice boot treat-
ment with Age Mas-
ter No 1 can be
performed by the op-
erator IAW the in-
structions given in
the AFM §8 Deicing
Boot Care
6 Months
-
30-10/154
Wing and horizontal
stabilizer airfoil de-ice
boots
Inspection/check
300 FH / 12 Months
12-B-30-10-00-00A-
313A-A
30-10/155
Inertial separation
system
Operational test
600 FH / 12 Months
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-05-40-00-00A-000B-A
UNCLASSIFIED
2021-12-04 Page 28