12
Use the BARO controls on the PFD Controllers and the ESIS to set the BARO settings in the following
table. Make sure that the PFD and ESIS altitude displays are within the limits.
Baro Setting (InHg)
Display Altitude (ft)
Display altitude (m)
30.98
976 ± 25
297 ± 7
29.92
11 ± 25
3 ± 7
28.86
-989 ± 25
-301 ± 7
27.82
-1989 ± 25
-606 ± 7
On the pitot static test set, adjust the static pressure and the pitot pressure to ambient.
QNH
Actual aircraft altitude ± 25
Actual aircraft altitude ± 7
13
On the Flight Control Panel (FCP) push the MINIMUMS rotary control.
14
Set the FCP MINIMUMS rotary control to give a Minimum Descent Altitude (MDA) of 1500 feet (457
m), (displayed on the PFD). Make sure that the MDA bug is shown at 1500 feet on the PFD altitude
tape.
15
On the maintenance panel, set the AIR/GND switch to AIR.
16
On the PFD Controllers, press the BARO rotary control to set 29.92 InHg.
17
On the Electronic Standby Instrument System (ESIS):
−
Thales ESIS
press the STD button to set 1013 hPa/29.92 InHg
−
L3 ESI-1000 ESIS
press the S button to set 1013 hPa/29.92 InHg
−
L3 EFD-750 ESIS
press the knob to set 1013 hPa/29.92 InHg/1013 mb.
18
Set the pitot pressure on the pitot static test set to 150 kts.
19
On the pitot static test set, set the reference altitudes in the following table. Make sure that the pilot
PFD, copilot PFD (if installed) and the ESIS altitude displays are within the limits.
Reference altitude (ft.)
PFD Altitude display (ft.)
Thales ESIS altitude dis-
play (ft.)
L3 ESIS altitude display
(ft.)
0
11 ± 20
11 ± 16
11 ± 20
100
111 ± 20
111 ± 16
111 ± 20
500
511 ± 20
511 ± 16
511 ± 20
1000
1012 ± 20
1012 ± 16
1012 ± 20
1500
1512 ± 25
1512 ± 25
1512 ± 25
2000
2012 ± 30
2012 ± 25
2012 ± 30
5000
5013 ± 40
5013 ± 30
5013 ± 40
10000
10017 ± 80
10017 ± 50
10017 ± 80
15000
15020 ± 110
15020 ± 60
15020 ± 110
20000
20029 ± 130
20029 ± 75
20029 ± 130
Reference altitude (m)
PFD Altitude display (m)
Thales ESIS altitude dis-
play (m)
L3 ESIS altitude display
(m)
0
3 ± 6
3 ± 5
3 ± 6
30
34 ± 6
34 ± 5
34 ± 6
152
156 ± 6
156 ± 5
156 ± 6
305
308 ± 6
308 ± 5
308 ± 6
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-34-14-00-00A-903B-A
UNCLASSIFIED
2021-12-04 Page 3