2.5
Wiring Harness Loop Clamp Check
2.5.1
Do a check of the six loop clamps that hold the wiring harness for the red beacon light, refer to Fig. 5 .
Make sure that:
−
The loop clamps are correctly secured to the de-ice pipe
−
The wires do not touch any pipes or structure.
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-57-00-00-00A-720B-A
UNCLASSIFIED
2021-12-04 Page 14