Table 2 600 FH or 12 Month Inspection (Continued from previous page)
Task number
Item Name
Task Description Data Module
Reference
Signature/Stamp Inspection
28-20/149
Firewall shutoff
valve
Operate FUEL
EMERG SHUT-
OFF lever and
make sure fire-
wall shutoff valve
opens and closes
fully to each dead
stop. Make sure
movement is free
and check if initial
pull out force at
lever outer end is
below 44.5 N (10
lbf)
-
29-10/151
Return line filter
differential pres-
sure indicator (If
installed)
Make sure that
it has not come
out. If indicator
found out, do the
inspection/check
procedure
12-B-29-10-04-
00A-313A-A
30-10/155
Inertial separation
system
Operational test
30-30/329
Probes de-ice
system
Functional test
12-B-30-30-20-
00A-903A-A
30-60/158
Propeller de-ice
system
Inspection/check 12-B-30-60-00-
00A-313A-A
or
12-B-30-60-00-
00A-313B-A
30-60/159
Propeller de-ice
system
Operational test
12-B-30-60-00-
00A-903A-A
or
12-B-30-60-00-
00A-903B-A
or
12-B-30-60-00-
00A-903C-A
or
12-B-30-60-00-
00A-903D-A
32-10/162
Main landing gear Lubricate
12-B-12-20-04-
00A-902A-A
32-10/163
Main landing gear
legs
Examine
-
32-10/164
Main landing gear
compartments
Examine
-
32-10/165
Main landing gear
shock struts
Check nitrogen
pressure
12-B-32-10-00-
00A-902A-A
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I