The green INERT SEP caption is ON
−
The CAS INERTIAL SEPARATOR caution message is OFF.
2.17
On the left inner cross bar panel, set the ICE PROTECTION - INERT SEP switch to CLOSED.
2.18
Wait for the bypass door to fully close.
2.19
Close this circuit breaker:
−
PROP DE-ICE (MAIN BUS).
2.20
De-energize the aircraft electrical system, refer to AMM 12-B-24-00-00-00A-901A-A.
Requirements after job completion
Required Conditions
Table 6 Required Conditions
Action / Condition
Data module/Technical publication
None
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-30-20-00-00A-903A-A
End of data module
UNCLASSIFIED
2021-12-04 Page 3