Preliminary Requirements
Required Conditions
Table 2 Required Conditions
Action / Condition
Data module/Technical publication
None
Support equipment
Table 3 Support equipment
Name
Identifications/References
Qty
Reference
Remark
Blanking cap
Part Local supply
AR
P3 pipe
Clean fresh water (drinking quali-
ty)
Part Local supply
AR
ECS blanking disc rig
Part T71-015
AR
P2.5 and P3
pipes
Engine compressor wash rig
Part T71-010
AR
Fuel
Part Local supply
AR
Safety clip - Circuit breaker hold
open
Part T12-030
AR
Spray tube
Part P&WC 32271
AR
Compressor wash rig fitting
Part T71-025
1
Post SB 71-012
Supplies
Table 4 Supplies
Name
Identifications/References
Qty
Reference
Remark
Cleaner (alkaline)
Part P01-001
AR
Anti-seize compound
Part P04-015
AR
Emulsifier
Part P01-003
AR
Lockwire (heat resistant)
Part P02-006
AR
0,6 mm (0.025
in) diameter
Lockwire (standard)
Part P02-007
AR
0,6 mm (0.025
in) diameter
Solvent
Part P01-009
AR
Triethanolamine
Part P01-002
AR
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-71-00-00-00A-250A-A
UNCLASSIFIED
2021-12-04 Page 2