3.2.3
Install the red flashing light Figure 1 [4] and gasket Figure 1 [5] on the access panel Figure 1 [6] with
the five screws Figure 1 [9].
3.2.4
Hold the access panel Figure 1 [6] in position and connect the electrical connectors A410J
Figure 1 [8].
3.2.5
Install a Cable tie (Pt.No. P09-008) as necessary to support the cable assembly Figure 1 [7].
3.2.6
Make sure the work area is clean and clear of tools and other items.
3.2.7
Install the access panel (tail cone) 32ET.
3.3
Install the top or bottom filament:
3.3.1
Install the filament Figure 1 [3] or Figure 2 [10] in the red flashing light Figure 1 [4] or Figure 2 [6].
3.3.2
Install the clamp ring and lens Figure 1 [1] or Figure 2 [8] and tighten the screw Figure 1 [2] or
Figure 2 [7].
3.4
Remove the safety clips and close these circuit breakers:
−
RED BEACON (GENERATOR 1 BUS)
−
EXT LTS GND OP (ESSENTIAL BUS)
−
NAV LIGHTS (MAIN BUS).
3.5
Do the operational test of the flashing red beacons, refer to AMM 12-B-33-40-00-00A-903A-A.
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-33-46-00-00A-920A-A
UNCLASSIFIED
2021-12-04 Page 4