Support equipment
Table 3 Support equipment
Name
Identifications/References
Qty
Reference
Remark
ESD wrist strap
Part Local supply
1
Safety clip (circuit breaker hold
open)
Part T12-030
AR
Supplies
Table 4 Supplies
Name
Identifications/References
Qty
Reference
Remark
Lockwire
Part P02-022
AR
Spares
Table 5 Spares
Name
Identifications/References
Qty
Reference
Remark
None
Safety Conditions
CAUTION
THE LDR IS AN ELECTROSTATIC DISCHARGE SENSITIVE DEVICE. USE AN ESD WRIST STRAP AND
CONNECT IT TO GROUND ON THE LDR BEFORE YOU START WORK ON THE LDR.
Note
To identify the AGE and tools used in this procedure refer to the List of AGE and Tools, TEM
12-B-00-00-00-00A-
060A-A
.
Note
To identify the consumable items used in this procedure refer to the Consumable Materials List, AMM
12-B-20-31-
00-00A-070A-A
.
Procedure
1
Removal
1.1
Open the access panel 31AB, refer to AMM 12-B-06-20-00-00A-040A-A.
1.2
On the CVFDR Panel in the battery bay, open and install a Safety clip (circuit breaker hold
open) (Pt.No. T12-030) on the following circuit breaker:
−
CVFDR POWER.
1.3
Make sure that the ESD wrist strap (Pt.No. Local supply) is securely connected to a good ground point
on the LDR.
1.4
Release the two DB 50 captive connector screws Figure 1 [6].
1.5
Disconnect the DB 50 connector Figure 1 [5] from the LDR Figure 1 [4].
1.6
Remove the lockwire Figure 1 [1] from bolts Figure 1 [2].
1.7
Remove the two bolts Figure 1 [2] and washers Figure 1 [3].
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-31-30-01-00A-920A-A
UNCLASSIFIED
2021-12-04 Page 2