Locate a Failed Memory Riser Card, DIMM, or CPU
Faulted Component
Memory Riser Indicator
CPU Indicator
DIMM Indicator
and use the DIMM Fault
Remind circuit.
■
To locate a failed CPU, look for the lit MR card Fault indicators and the lit
CPU Fault indicator.
When a CPU is in a fault state, the Fault indicators for the CPU and both MR cards
associated with the CPU light when the system Fault Remind button is pressed.
The following illustration shows the lit indicators for a failed CPU, P0. In this example,
the Fault indicators for memory riser cards, P0/MR0 and P0/MR1 are lit, as is the Fault
indicator for CPU, P0.
“CPU Fault Indicators” on page 84
■
To locate a failed MR card, look for the MR card Fault indicator.
When an MR card is in a fault state, the Fault indicator for the card lights when the system
Fault Remind button is pressed. The indicator is visible through the small hole on top of
the card.
88
Oracle Server X5-4 Service Manual • December 2015
Содержание X5-4
Страница 1: ...Oracle Server X5 4 Service Manual Part No E56396 03 December 2015 ...
Страница 2: ......
Страница 10: ...10 Oracle Server X5 4 Service Manual December 2015 ...
Страница 14: ...14 Oracle Server X5 4 Service Manual December 2015 ...
Страница 21: ...Server Subsystems Overview Two CPU Block Diagram Oracle Server X5 4 Overview 21 ...
Страница 36: ...36 Oracle Server X5 4 Service Manual December 2015 ...
Страница 68: ...68 Oracle Server X5 4 Service Manual December 2015 ...
Страница 178: ...178 Oracle Server X5 4 Service Manual December 2015 ...
Страница 272: ...272 Oracle Server X5 4 Service Manual December 2015 ...
Страница 281: ...About the BIOS Setup Utility Keywords Main DIMM Information Processor 0 DIMMs BIOS Setup Utility Menu Options 281 ...
Страница 293: ...About the BIOS Setup Utility Keywords Memory Configuration Numa Patrol Scrub BIOS Setup Utility Menu Options 293 ...
Страница 307: ...About the BIOS Setup Utility Keywords Advanced Network Stack BIOS Setup Utility Menu Options 307 ...
Страница 327: ...About the BIOS Setup Utility Keywords IO Add In Cards Slot 1 Slot 11 BIOS Setup Utility Menu Options 327 ...
Страница 331: ...About the BIOS Setup Utility Keywords OSA Internal Support Disabled Enabled BIOS Setup Utility Menu Options 331 ...
Страница 340: ...340 Oracle Server X5 4 Service Manual December 2015 ...