Install a Memory Riser Card
Install a Memory Riser Card
When servicing the components in this section, unplug the AC power cords and use ESD
protection.
Use this procedure to install a memory riser (MR) card into its slot.
Before You Begin
■
For serviceability considerations, see
“Component Serviceability” on page 70
.
■
For DIMM designation information, see
“Component Designations” on page 73
.
■
For reference information, see
“Memory Riser Card and DIMM Reference” on page 154
.
1.
Ensure that all populated and unpopulated DIMM slot ejector levers are in the
closed and locked position.
Caution -
Component damage. Open DIMM ejector levers can break off during the installation
of the memory riser (MR) card. All populated and unpopulated DIMM slot ejector levers on the
MR card must be in the fully-closed and locked position before installing the card in the server.
2.
Install the MR card as follows:
a.
Ensure that the MR card ejector levers are in the closed position.
The ejector levers are only used to remove a MR card and are
not
used to install a card.
See the illustration below.
b.
Align the MR card with its slot on the motherboard.
The DIMMs on the card must face the left (when looked at from the front of the server).
c.
Carefully lower the card on to the slot.
Ensure that the card is in the provided card guide channels. See the illustration below.
152
Oracle Server X5-4 Service Manual • December 2015
Содержание X5-4
Страница 1: ...Oracle Server X5 4 Service Manual Part No E56396 03 December 2015 ...
Страница 2: ......
Страница 10: ...10 Oracle Server X5 4 Service Manual December 2015 ...
Страница 14: ...14 Oracle Server X5 4 Service Manual December 2015 ...
Страница 21: ...Server Subsystems Overview Two CPU Block Diagram Oracle Server X5 4 Overview 21 ...
Страница 36: ...36 Oracle Server X5 4 Service Manual December 2015 ...
Страница 68: ...68 Oracle Server X5 4 Service Manual December 2015 ...
Страница 178: ...178 Oracle Server X5 4 Service Manual December 2015 ...
Страница 272: ...272 Oracle Server X5 4 Service Manual December 2015 ...
Страница 281: ...About the BIOS Setup Utility Keywords Main DIMM Information Processor 0 DIMMs BIOS Setup Utility Menu Options 281 ...
Страница 293: ...About the BIOS Setup Utility Keywords Memory Configuration Numa Patrol Scrub BIOS Setup Utility Menu Options 293 ...
Страница 307: ...About the BIOS Setup Utility Keywords Advanced Network Stack BIOS Setup Utility Menu Options 307 ...
Страница 327: ...About the BIOS Setup Utility Keywords IO Add In Cards Slot 1 Slot 11 BIOS Setup Utility Menu Options 327 ...
Страница 331: ...About the BIOS Setup Utility Keywords OSA Internal Support Disabled Enabled BIOS Setup Utility Menu Options 331 ...
Страница 340: ...340 Oracle Server X5 4 Service Manual December 2015 ...