Description of fields
Field
Option
Description
Time limit
for predict-
ing target
location
From
1 s
to
5 s
If the target is lost when
Aim at target:
With lock
the path of the prism is predicted
for the selected number of seconds.
If no target
found after
prediction
then
Wait & lock
Perform no search after prediction.
Start fine
search
Perform search after prediction with ATRplus
in a dynamic
Fine search window
.
Start Cube-
Search
Perform search after prediction with Power-
Search. Activate PowerSearch on the
Power-
Search window
page.
Turn to last
measured
point
If the target is lost when
Aim at target:
With lock
, then the instrument turns back
to the last stored point. The field of view is
disabled while the instrument is reposition-
ing.
Next step
Page
changes to the
PowerSearch window
page.
Key
Description
OK
To accept changes and return to
Leica Captivate - Home
.
Set
To define new PowerSearch window.
Centre
To centre the PowerSearch window to the current position of
the telescope.
Show
To position the telescope to corners of PowerSearch window.
Page
To change to another page on this panel.
Description of fields
Field
Option
Description
Use Power-
Search win-
dow
Check box
If checked, PowerSearch searches in the
defined window.
Target Search,
PowerSearch window
page
Settings - TS instrument
255
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...