☞
Measure Foresight from the toolbox for apps cannot be used when
this setup method was used.
•
The measured setup points must have 3D coordinates. 1D (height only) or
2D (position only) coordinates are not allowed.
•
Distances must be measured to at least three target points.
•
The scale factor of 1 is used. A user defined scale factor is ignored.
To check the current scale factor select
Current setup
in the
Instrument
.
The scale factor is defined on the
TS scale
page when creating or editing
a job.
In
Total Station Setup
, select
Setup method:
Orientate to object
. Press
OK
.
In
Setup Details
type in the required information. Press
OK
.
For a description of the
Measure Target
panel, refer to "50.6.2 Multiple back-
50.7
Setup Results
The results panel is displayed after pressing
Calculate
in the
Measure Target
panel. The results panel is part of the
Multiple backsights
,
Transfer height
,
Resection
,
Orientate to line
and
Orientate to object
setup methods.
After three measurements to known targets, the calculations can be done
using the robust method or the least squares method.For
Resection
, the cal-
culations can also be done using the Helmert method.For
Orientate to
object
, the calculations are always done using the robust method. For
Orien-
tate to line
, no adjustment is applicable.
After the setup is set, all following measurements will be related to this new
setup and orientation.
For information on camera and images refer to "32 Camera & Imaging".
Key
Description
Set
To set the orientation, to store all setup data and exit the
app.
For
Transfer height
:
To store all setup data and exit the app.
Requirements
Access
☞
Description
☞
Setup Results,
Results page
Setup - TS
887
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...