GS12_041
N
H
N
E
Position determination with satel-
lites appearing in all four quadrants.
Height determination with satellites
appearing in two quadrants.
Description
The
C
oordinate
Q
uality is an indicator for the estimated quality of the point
coordinates. The coordinate quality of the measurements is used in point aver-
aging.
Type
Description
Est 3D CQ
Estimated 3D coordinate quality of computed position.
Est 2D CQ
Estimated plan coordinate quality of computed position.
Est 1D CQ
Estimated height coordinate quality of computed position.
Vertical angles are always assuming zenith angles and not elevation angles.
Standard deviations of circle readings relate to one face measurements.
ρ
=
200
π
Standard deviation of circle reading
σ
Hz, V
σ
Hz, V
ρ
rad
gon
=
σ
Hz,V Standard deviation of circle
reading if
σ
Hz =
σ
V.
σ
Hz: Standard deviation of
horizontal circle reading.
σ
V: Standard deviation of
vertical circle reading.
Standard deviation of distance
measurement
σ
D
= c
D
+ ppm * D
σ
D
Standard deviation of dis-
tance measurement.
cD
Constant part of EDM accu-
racy.
ppm ppm part of EDM accuracy.
D
Slope Distance.
1D estimated coordinate quality
1D CQ =
σ
2
D
* cos
2
V +
σ
2
Hz, V
* D
2
* sin
2
V
1D CQ Estimated coordinate qual-
ity of the height.
V
Zenith angle.
Coordinate quality for
TS
Glossary
1043
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...