For
Setup method:
Resection
and
Setup method:
Multiple backsights
, the
settings on this page apply.
Description of fields
Field
Option
Description
Automati-
cally turn TS
to next tar-
get point
Check box
When this box is checked, the instrument
positions horizontally and vertically to the
point.
Measure
target
points while
measuring
other points
(on-the-fly)
Check box
When this box is checked, the setup points
can be measured together with the survey
points. It is not necessary to complete the
setup before measuring survey points. Until
you select
Set
in
Setup Results
, this type
of setup is regarded as incomplete.
Calculate &
show scale
from the
measure-
ments made
to targets
Check box
Only available if
Scale TS measurements
is
unchecked in the job properties
TS scale
page.
If checked, a setup scale is calculated from
the target observations. You can apply this
new scale (calculated ppm + current ppm =
new ppm) to all survey observations, includ-
ing the setup observations, from that setup.
If not checked, then the calculated ppm is
not displayed and therefore not applied to
any survey observations.
For resec-
tions use
Helmert
method for
calculations
Check box
Helmert calculation is used.
Height
weighting
1/distance
or
1/
distance²
Available when
For resections use Helmert
method for calculations
is checked. To
change the distance weighting that is used in
the calculation of the setup height in the
resection.
Edit the
default
setup limits
Check box
Check to type in values for standard devia-
tion, position and height accuracy. If the lim-
its are exceeded, a message is shown when
Calculate
is selected.
Orientation
limit
Editable field
Available when
Edit the default setup lim-
its
is checked. Define a limit for the standard
deviation of the orientation.
Position
limit
Editable field
Available when
Edit the default setup lim-
its
is checked. Define a position accuracy of
the target point.
Height limit
Editable field
Available when
Edit the default setup lim-
its
is checked. Define a height accuracy of
the target point.
Settings,
Advanced page
874
Setup - TS
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...