Instrument
Settings
Third-party total station -
Topcon
1. Total station ppm/scale:
•
Atmospheric ppm = 0
•
Geometric ppm = 0 or scale factor = 1
•
Prism constant = 0 (non-motorised
instruments only)
•
The vertical angle on the total station
must be set to zenith for all Topcon
instruments.
•
The angular unit on both the total sta-
tion and controller must match
These settings ensure that the correct
coordinates are calculated at the CS. It is
still possible to apply the relevant atmos-
pheric and geometric ppm/scale factor val-
ues. These values must then be set on the
CS.
2. Communication settings:
•
The communication settings on the TS
must match the default parameters for
that particular instrument type as seen
on the CS.
•
On motorised Topcon total stations, for
example GTS800 and above, set the
communication values through
Prog
\
Ext.
Link
\
Setting
\
RS232
.
•
For non-motorised instruments, ensure
that the total station is in the measure-
ment panel when trying to connect.
3. External Link mode
•
To connect to motorised Topcon total
stations, for example GTS800 and above,
set the external link mode through
Prog
\
Ext. Link
\
Execute
.
4. Required cable:
•
TDS DB9 Data Cable (148 SCGTSSOKTOP
– Topcon/Sokkia)
Third party total station -
Sokkia
1. Total station ppm/scale:
•
Atmospheric ppm = 0
•
Geometric ppm = 0 or scale factor = 1
•
Prism constant = 0
•
The vertical angle display setting must be
the same on the CS and the total station
These settings ensure that the correct
coordinates are calculated at the CS. It is
still possible to apply the relevant atmos-
pheric and geometric ppm/scale factor val-
ues. These values must then be set on the
CS.
160
Connections - TS connection wizard
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...