Description of fields
Field
Option
Description
Connect
using
How the instrument is connected.
☞
For CS35, only Bluetooth connec-
tions can be configured.
Radio han-
dle
,
Blue-
tooth
,
External
radio
When
External radio
is selected, choose the
type of
External radio
in use.
Cable
For TS16: Serial cable connection.
For MS60/TS60: USB cable connection. Select
Cable
for a USB cable connection. Use the
cables GEV234 (LEMO - USB), GEV237 (LEMO
- LEMO) or GEV261 (combined RS232/USB
cable).
Cable RS232
Available when
A software other than
Leica Captivate
is checked in the previous
panel.
Available on MS60/TS60 to configure serial
connection.
WLAN
Available when
A software other than
Leica Captivate
is checked in the previous
panel. Requires settings in WinCE.
Next step
Next
changes to the next panel.
IF
THEN
connected using RadioHandle
Next
changes to the next panel.
The RadioHandle is detected automatically, if
it is plugged into the TS. The name of the
RadioHandle is then displayed.
If the RadioHandle is not plugged onto the
TS, then select the RadioHandle which is
used. Press
Next
.
☞
The RH17 can only be connected
to a CS20 equipped with a CTR20.
connected using TCPS27/
TCPS28
Select the TCPS connected and press
Next
.
Refer to "15.2 Connection Using TCPS".
connected using TCPS29/
TCPS30
Select the TCPS connected and press
Next
.
Further settings are not required.
connected using cable
refer to "15.3 Connection Using Cable".
a MS60/TS60 is connected
using cable and Leica Capti-
vate is running on the field
controller
the system sets all the parameters to be able
to connect to a CS using USB interface from
port 1.
Connections - CS connection wizard
163
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...