Field
Option
Description
No time out
There is no automatic closure, only by user
interaction in a message panel. When a mes-
sage panel appears, press
Yes
to close.
1sec
to
60sec
All message panels are automatically closed
as defined by these individual time settings.
Re-measure
points
To define the action if a target point cannot
be measured.
Never
The target point is skipped and the next tar-
get point in the list is measured.
Automati-
cally
The measurement to the target point is
repeated automatically.
☞
The option for
Measure distance
in
Measure & Target
is also
changed for the repeated meas-
urement. If the option is changed,
then it is applied to all following
sets.
Manually
The measurement to the target point can be
repeated manually or the target point can be
skipped.
Sort points
by Hz angle
Check box
Check this box to sort the target points auto-
matically. The instrument works in a clock-
wise direction and finds the shortest path to
move between the target points.
Define time
when sets
should be
measured
(timer mon-
itoring)
Check box
When this box is checked, automatic moni-
toring of target points is activated.
When this box is not checked, automatic
monitoring of target points is not activated.
The Sets of Angles app applies.
Next step
Page
changes to the
Tolerances
page.
Description of fields
Field
Option
Description
Use toleran-
ces
Check box
If checked, the entered horizontal, vertical
and distance tolerances are checked during
the measurements to verify accurate pointing
and measurements.
Hz tolerance
Editable field
Tolerance for horizontal directions.
V tolerance
Editable field
Tolerance for vertical directions
Settings,
Tolerances page
852
Sets of Angles - TS
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...