Appendix G
Event Input Notify Message Format
With GS25, a message can be created. This message provides information
about
•
the fact that an event was detected by the receiver
•
the time when the event was detected.
The message can be in ASCII or in binary format. It is sent to a connected
device, for example a PC.
Refer to "18.12 Event input 1/Event input 2" for configuring the event input
interface.
$PLEIR,HPT,134210000,1203*17
$PLEIR,EIX,sssssssss,tttttttt,nnnn,cccc,dddd*hh<CR><LF>
Field
Description
$PLEIR
Header
EIX
Message identifier.
X = 1 for port E1
X = 2 for port E2
ssssssssss
GPS time of week of event in ms
tttttttt
GPS time of week of event in ns
nnnn
GPS week number
cccc
Event count
dddd
Event pulse count
This is the count of all pulses including those violating the
specified accuracy limit boundary conditions set in
Event
Input 1
/
Event Input 2
,
Event input
page. This allows
determination of missed events.
*hh
Checksum
<CR>
Carriage return
<LF>
Line feed
$PLEIR,EI2,292412000,28932,1203,203,1*70
Description
Example
Syntax in ASCII
Description of the
fields
Example
1034
Event Input Notify Message Format
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...