detects a prism, the rotation of the instrument is stopped. Afterwards an auto-
matic aiming measurement in the vertical direction is performed.
a b
c
TS_006
a
EGL
b
Transmitter
c
Receiver
If a PS filter is active, PowerSearch ignores the prisms defined in the filter.
If a PS window is defined and active, PowerSearch is executed within the
defined limits.
If the search window is not defined and PowerSearch is started, the prism is
searched for with PowerSearch in the 360° window. The default search with
PowerSearch consists of a short swing in anti-clockwise direction followed by a
complete 360° turn in clockwise direction. If a prism is detected the movement
is stopped and an automatic aiming search is performed.
A PowerSearch filter can be applied to exclude disturbing prisms from Power-
Search.
The PowerSearch filter can be defined in two ways:
1
.
Performing a PowerSearch scan:
Select the
Filter learn
bubble icon in the
Aim & Search
icon pop-up bub-
ble.
2
.
Adding setup points to the PowerSearch filter:
In the
Setup
app, check
Add target points to the PowerSearch filter
in the
Settings
,
General
page.
The PowerSearch scan finds prisms and other reflective spots in the surround-
ing of the instrument. Around each found prism or reflective spot, an exclusion
area is defined. The exclusion area has the dimension of Hz = ± 1 gon,
V = ± 50 gon and d = ± 12 m.
After defining the filter, the filter is switched on:
Filter on
is displayed in the
Aim & Search
icon pop-up bubble.
☞
☞
360° search
PowerSearch filter
TS Functions
393
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...