This panel is displayed when prompting is configured in
Prompt Before Stor-
ing
and when storing a point with
Store
or
Measure
.
☞
Only the fields relating to the ticked check boxes in
Prompt Before
Storing
are shown.
25.3
GS quality control
The settings on this panel define the limits for coordinate quality accepted for
point occupations.
Select
Leica Captivate - Home: Settings
\
Point storage
\
GS quality control
.
Key
Description
OK
To accept changes.
Parameter
To configure the time interval after which a point occupation
can be stopped automatically.
Page
To change to another page on this panel.
Description of fields
Field
Option
Description
Automati-
cally stop
point meas-
urement
Check box
Activates a selectable list for the stop criteria.
Stops the measurements automatically when
the parameter defined for
Stop measure-
ment based on
reaches 100 %.
Stop meas-
urement
based on
Defines the method used for
Automatically
stop point measurement
. The setting
determines the computation and value to be
shown in the Measure panel. Parameters for
the selected method are defined with
Parameter
.
Accuracy
or
Positions
Available when working with real-time
device. Records observations between press-
ing
Measure
and
Stop
. Recommended for
normal real-time applications. Refer to the
diagram below.
Enter the Following
Description
Access
GS Quality Control,
General page
300
Settings - Point storage
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...