Height limits below the design surface are entered as negative values. For
example, the
Lower height limit
with -10 mm in the previous diagram. Using
the signs of the height limits, it is also possible to cover situations like the one
shown in the following diagram, with a valid range between -10 to -50 mm
below the design surface.
a
c
b
Road_088
a
Design surface
b
Upper height limit
c
Lower height limit
Description of fields
Field
Option
Description
Check dif-
ferences
before stor-
ing
Check box
When this box is checked, a position check is
done when storing a staked or checked
point. When the defined tolerance is excee-
ded, the stake out/check can be repeated,
skipped or stored.
When this box is not checked, no quality
check is done during stake out/check of
points.
Differences
to check
☞
Depending on this selection the
following lines are enabled/disa-
bled.
Chainage,
offset &
height
Check for chainage, horizontal offset and
height.
Chainage &
offset
Check for chainage and horizontal offset.
Position &
height
Check for 2D position and height.
Position
Check for 2D position.
Height
Check for height.
Profile
Available for Tunnel. Check for distance from
design profile.
Chainage
limit
From
0.001
to
100
Maximum difference in chainage.
Offset limit
From
0.001
to
100
Maximum horizontal offset from defined
position.
Position
limit
From
0.001
to
100
Maximum radial horizontal distance.
Upper
height limit
From
-100
to
+100
Maximum height difference.
Lower
height limit
From
-100
to
+100
Maximum height difference.
Profile tol-
erance
From
0.001
to
100
Available for Tunnel. Permitted distance from
design profile.
Roads - General
629
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...