LEO2-Ei

Eigensicheres digitales Manometer mit Min.-/Max.-Anzeige.

Intrinsically Safe Manometer with Min.-/Max.-Display. 

Manomètre numérique de sécurité intrinsèque avec affichage Min./Max..

zum Einsatz in explosionsgefährdeten Bereichen

for use in Hazardous Applications

pour utilisation en zones explosibles

Min.-/Max.-Druckwert

Min.-/Max. Pressure Value

Valeur de pression Min./Max.

Aktueller Druckwert

Actual Pressure Value

Valeur de pression actuelle

SELECT

ENTER 

Min./Max.

Druckanschluss

Pressure Connection

Raccord pression

Содержание LEO2-Ei

Страница 1: ...ue avec affichage Min Max zum Einsatz in explosionsgefährdeten Bereichen for use in Hazardous Applications pour utilisation en zones explosibles Min Max Druckwert Min Max Pressure Value Valeur de pression Min Max Aktueller Druckwert Actual Pressure Value Valeur de pression actuelle SELECT ENTER Min Max Druckanschluss Pressure Connection Raccord pression ...

Страница 2: ...ENTER activates the selected function or pressure unit The right key is also used to switch between the Min and Max pressure value Turn on Pressing the SELECT key turns the instrument on The instru ment first displays the full scale pressure range top display and the software version year week The instrument is then ready for use and indicates the actual pressure top display and the last measured ...

Страница 3: ...a PSI kp cm2 Example Setting a new pressure unit mbar Turn on the instrument by shortly pressing SELECT Wait for the instrument s measuring mode 3 s Press the SELECT key 3 times MANO appears Press ENTER ZERO SEt appears Press SELECT ZERO rES appears Press SELECT CONT on or CONT off appears Press SELECT bar appears Press SELECT mbar ap pears Press ENTER The new pressure unit mbar is set The instrum...

Страница 4: ...NTER key LEO2 Ei returns to the measuring mode without changing any settings 3 Turning LEO 2 Ei on and off does not influence any of the previous settings 4 If the CONT on function is activated it is indicated with a flashing sign on the display OFF flashes when CONT on is set 5 If a pressure can not be represented on the display OFL overflow or UFL underflow appears on the display 6 If the actual...

Страница 5: ... swivel adapter can be tightened with a max torque of 50 Nm Battery Change Battery Life When the battery starts weak ening a low battery warning BAT LOW will appear in the display Battery change Open the bat tery compartment and change the battery Type RENATA CR 2430 Please use a coin for opening the battery box to prevent da mage to the battery cover When reassembling make sure that the O ring re...

Страница 6: ... sure zero for the ranges 61 bar absolute is at vacuum 0 bar absolute For relative pressure measurements activate ZERO SEt at ambient pressure Instruments 61 bar absolute or instruments with a relative pressure sensor label marked with Range rel are calibrated with the zero at atmospheric pressure General Safety Instructions When installing and operating the digital manometer attention should be p...

Страница 7: ...ery type must be used in explosive atmospheres Renata CR 2430 The battery may be changed in side the zone with a potentially explosive atmosphere Do not conduct such processes in close proximity which gene rate charged particles air ioniser high voltage electrodes etc Increases the maximum media temperature at the transducer 80 C it is the duty of the final user to make own safety clarifi cations ...

Страница 8: ...he following norms for this Intrinsically Safe Mano meter LEO2 Ei are applied and the EC examination certifi cate under LCIE 01 ATEX 6001 X Issue 04 is given This declaration is given for the manufacturer in full responsibility by Déclaration UE de conformité Nous attestons que les produ its Manomètres numériques LEO2 Ei de sécurité intrinsèque répondent aux exigences pré vues par les directives d...