GD310-UL series VFD
Basic operation instruction
-168-
P05.00
( HDI input type selection(
P05.40
( HDI high speed pulse function selection(
0
1
2
0
1
P17.22
Length clear
P08.19 (the set length)
P08.20 (the actual length)
P08.20=P08.22*P08.23*P08.24*f
HDI
/P08.21
P08.20>P08.19 ?
Digital output 20
Length arrival
( HDI input frequency(
Terminal function 32
Length reset
0
Y
N
P17.17
The length value
Note
: the length arrival belongs to pulse output and the lasting time is 200ms.
Function
code
Name
Description
Default
value
P05.00
HDI input selection
0: High pulse input.
1: Digital input.
0
P05.49
HDI high-speed pulse
input function
selection
0: Frequency setting input
1: Counter input
2: Length counting input
0
P05.01
–
P05.09
Digital input function
selection
32: Length reset
P06.01
–
P06.04
Digital output function
selection
20: Length arrival
P08.19
Setting length
0
–65535m
0
P08.20
Actual length
0
–65535m
0
P08.21
Pulse per rotation
1
–10000
1
P08.22
Axle perimeter
0.01
–100.00cm
10.00
P08.23
Length ratio
0.001
–10.000
1.000
P08.24
Length correcting
coefficient
0.001
–1.000
1.000
P17.17
Length
0
–65535
0
P17.22
HDI input frequency
Display HDI input frequency
Range: 0.00
–50.00kHz
0.00 kHz
7.19 Fault procedure
Goodrive310-UL series VFDs provide sufficient fault procedure information for the convenience of
user’s application.
Содержание GD310-011P-4-UL
Страница 1: ......
Страница 269: ...6 6 0 0 1 0 0 3 9 3 ...