GD310-UL series VFD
Basic operation instruction
-156-
Function
code
Name
Description
Default
value
23: MODBUS communication virtual terminals
output
24: PROFIBUS/CANopen communication virtual
terminals output
25: Ethernet communication virtual terminals
output
26: Voltage establishment finished
27
–30: Reserved
P06.05
Polarity of output
terminals
0x00
–0x0F
0x00
P06.06
Y switch-on delay time 0.000
–50.000s
0.000s
P06.07
Y switch-off delay time 0.000
–50.000s
0.000s
P06.08 HDO switch-on delay time 0.000
–50.000s (valid only when P06.00=1)
0.000s
P06.09 HDO switch-off delay time 0.000
–50.000s (valid only when P06.00=1)
0.000s
P06.10 RO1 switch-on delay time 0.000
–50.000s
0.000s
P06.11 RO1 switch-off delay time 0.000
–50.000s
0.000s
P06.12 RO2 switch-on delay time 0.000
–50.000s
0.000s
P06.13 RO2 switch-off delay time 0.000
–50.000s
0.000s
P07.40
Output terminals state at
present fault
/
0
P17.13
Digital output terminals
state
/
0
7.13 Simple PLC
Simple PLC function is also a multi-step speed generator. The VFD can change the running frequency,
direction to meet the need of processing according to the running time automatically. In the past, this
function needs to be assisted by external PLC, but now the VFD can realize this function by itself.
The series VFDs can control 16-stage speed with 4 groups of ACC/DEC time.
The multi-function digital output terminals or multi-function relay output an ON signal when the set
PLC finishes a circle (or a stage).
Running parameter
setting in all stages
in PLC
Restart from the
first stage
Restart form the
frequency of the
pause stage
Stop after running
one time
Run at the final
value after running
for one time
Cycle
0
1
2
P10.00
(
simle PLC
)
PLC method
0
1
0
1
0
1
Normal running
P10.01
(
simple PLC memory seleciton
)
Power off
without memory
Power off
with memory
P10.36
(
PLC starting selection
)
P17.00
Power off
during running
Terminal function 23
Simple PLC stop reset
Set frequency