GD310-UL series VFD
Function parameter
-93-
Function
code
Name
Description
Default
value
Modify
P10.01
Simple PLC
memory
0: Power loss without memory
1: Power loss with memory; PLC record the running
stage and frequency when power loss.
0
○
P10.02
Multi-step
speed 0
The frequency setting range of stage 0
–15:
-100.0
–100.0%
,
100.0% of the frequency setting
corresponds to the max Frequency P00.03.
The operation time setting of stage 0
–15: the time
unit is determined by P10.37. When selecting simple
PLC running, set P10.02
–P10.33 to define the
running frequency and time of all stages.
Note
:
The symbol of multi-step determines the
running direction of simple PLC. The negative value
means reverse rotation.
P10.02
P10.04
P10.06
P10.32
P10.30
P10.28
DEC time
(2 stages)
ACC time
(2 stags)
P10.03
P10.05
P10.07
P10.31
P10.33
If multi-step speed operation is selected, multi-step
speeds are in the range of --f
max
–f
max
and it can be
set continuously.
Goodrive310-UL series VFDs can set 16 stages
speed, selected by the combination of multi-step
terminals 1
–4 (select the setting by S terminals, the
corresponding function codes are P05.01
–P05.09),
corresponding to the speed 1 to speed 15.
Output frequency
Terminal 1
Terminal 2
Terminal 3
Terminal 4
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
t
t
t
t
t
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0.0%
○
P10.03
Running time
of step 0
0.0s
○
P10.04
Multi-step
speed 1
0.0%
○
P10.05
Running time
of step 1
0.0s
○
P10.06
Multi-step
speed 2
0.0%
○
P10.07
Running time
of step 2
0.0s
○
P10.08
Multi-step
speed 3
0.0%
○
P10.09
Running time
of step 3
0.0s
○
P10.10
Multi-step
speed 4
0.0%
○
P10.11
Running time
of step 4
0.0s
○
P10.12
Multi-step
speed 5
0.0%
○
P10.13
Running time
of step 5
0.0s
○
P10.14
Multi-step
speed 6
0.0%
○
P10.15
Running time
of step 6
0.0s
○
P10.16
Multi-step
speed 7
0.0%
○
P10.17
Running time
of step 7
0.0s
○
P10.18
Multi-step
speed 8
0.0%
○
P10.19
Running time
of step 8
0.0s
○