GD310-UL series VFD
Function parameter
-61-
Function
code
Name
Description
Default
value
Modify
at low
frequency of
motor 1
occur to the motor at some frequency, especially the
motor with big power. The motor cannot run stably or
overcurrent may occur. These phenomena can be
canceled by adjusting this parameter.
Setting range of P04.10: 0
–100
Setting range of P04.11: 0
–100
Setting range of P04.12: 0.00Hz
–P00.03 (the max
frequency)
P04.11
Vibration
control factor
at high
frequency of
motor 1
10
○
P04.12
Vibration
control
threshold of
motor 1
30.00Hz
○
P04.13
Motor 2 V/F
curve setting
This group of parameters defines the V/F setting
means of Goodrive310-UL motor 2 to meet various
requirements of different loads. See P04.00
–P04.12
for the detailed function code instruction.
Note
:
P04 group includes two sets of V/F parameters
of the motor which cannot display simultaneously.
Only the selected V/F parameter can be shown. The
motor selection can be defined by terminals function
“the shift between motor 1 and motor 2”
0
◎
P04.14
Torque boost
of motor 2
0.0%
○
P04.15
Torque boost
close of motor
2
20.0%
○
P04.16
V/F frequency
1 of motor 2
0.00Hz
○
P04.17
V/F voltage 1
of motor 2
00.0%
○
P04.18
V/F frequency
2 of motor 2
00.00Hz
○
P04.19
V/F voltage 2
of motor 2
00.0%
○
P04.20
V/F frequency
3 of motor 2
00.00Hz
○
P04.21
V/F voltage 3
of motor 2
00.0%
○
P04.22
V/F slip
compensation
gain of motor 2
100.0%
○
P04.23
Vibration
control factor
at low
frequency of
motor 2
In SVPWM control mode, current fluctuation may
occur to the motor on some frequency, especially the
motor with big power. The motor cannot run stably or
overcurrent may occur. These phenomena can be
10
○