GD310-UL series VFD
Basic operation instruction
-145-
Set value
Function
Instructions
15
Setting value 2 of MODBUS
communication
-1000
–1000, 1000 corresponds to 100.0%
16
Setting value 1 of
PROFIBUS/CANOPEN communication
-1000
–1000, 1000 corresponds to 100.0%
17
Setting value 2 of
PROFIBUS/CANOPEN communication
-1000
–1000, 100 corresponds to 100.0%
18
Setting value 1 of Ethernet
communication
-1000
–1000, 1000 corresponds to 100.0%
19
Setting value 2 of Ethernet
communication
-1000
–1000, 100 corresponds to 100.0%
20
–21
Reserved
22
Torque current (relative to the rated
current of the motor)
0
–2 times of the rated current of the motor
23
Exciting current (relative to the rated
current of the motor)
0
–2 times of the rated current of the motor
24
–30
Reserved
Related parameters list:
Function
code
Name
Description
Default
value
P06.00
HDO output
0: Open collector pole high speed pulse
output
1: Open collector pole output.
0
P06.14
AO1 output
0: Running frequency
1: Set frequency
2: Ramp reference frequency
3: Running rotation speed
4: Output current
(relative to the rated current of the VFD)
5: Output current
(relative to the rated current of the motor)
6: Output voltage
7: Output power
8: Set torque value
9: Output torque
10: AI1 input value
11: AI2 input value
12: AI3 input value
0
P06.15
AO2 output
0
P06.16
HDO high-speed pulse
output
0