GD310-UL series VFD
Function parameter
-86-
Function
code
Name
Description
Default
value
Modify
P08.41
Overmodulatio
n selection
LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overmodulation; in zone 1
1: Heavy overmodulation; in zone 2
01
◎
P08.42
Keypad data
control
0x000
–0x1223
LED ones: frequency enable selection
0: Both
∧
/
∨
keys and digital potentiometer
adjustments are valid
1: Only
∧
/
∨
keys adjustment is valid
2: Only digital potentiometer adjustments is valid
3: Neither
∧
/
∨
keys nor digital potentiometer
adjustments are valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: Valid for all frequency setting manner
2: Invalid for multi-step speed when multi-step speed
has the priority
LED hundreds: action selection during stopping
0: Setting is valid
1: Valid during running, cleared after stopping
2: Valid during running, cleared after receiving the
stop command
LED thousands:
∧
/
∨
keys and digital
potentiometer integral function
0: The integral function is valid
1: The integral function is invalid
0x0000
○
P08.43
Integral ratio
of the keypad
potentiometer
0.01
–10.00s
0.10s
○
P08.44
UP/DOWN
terminals
control
0x000
–0x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: All frequency means are valid
0x000
○