GD310-UL series VFD
Basic operation instruction
-139-
Current given
channel
P00.09
Multi-function terminal
function 13
Switch from A channel to
B channel
Multi-function terminal
function 14
Switch from
combination setting to
A channel
Multi-function terminal
function 15
Switch from
combination setting to
B channel
B
A
/
/
A+B
/
A
B
A-B
/
A
B
Max (A, B)
/
A
B
Min (A, B)
/
A
B
Note
: "/" means the multi-function terminal is invalid under the current given channel.
When select multi-function terminal UP (10) and DOWN (11) to set the internal assistant frequency,
P08.44 and P08.45 can be set to increase or decrease the set frequency quickly.
Sx
Sy
Up terminal function
selection=10
DOWN terminal function
selection=11
UP terminal state
DOWN terminal state
T
F
T
T
UP terminal frequency increasing integral rate P08.44
DOWNterminal frequency increasing integral rate P08.45
Related parameters list:
Function
code
Name
Description
Default
value
P00.03
Max. output frequency P00.04
–400.00Hz
60.00Hz
P00.04
Upper limit of the
running frequency
P00.05
–P00.03
60.00Hz
P00.05
Lower limit of the
running frequency
0.00Hz
–P00.04
0.00Hz
P00.06
A frequency command 0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI setting
5: Simple PLC program setting
6: Multi-step speed running setting
0
P00.07
B frequency command
0
Содержание GD310-011P-4-UL
Страница 1: ......
Страница 269: ...6 6 0 0 1 0 0 3 9 3 ...