![INVT GD310-011P-4-UL Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/invt/gd310-011p-4-ul/gd310-011p-4-ul_operation-manual_2085698121.webp)
GD310-UL series VFD
Function parameter
-113-
Function
code
Name
Description
Default
value
Modify
P17.28
ASR controller
output
The percentage of the rated torque of the relative
motor, display ASR controller output
Range: -300.0%
–300.0% (rated motor current)
0.0%
●
P17.29
Magnetic pole
angle of SM
Display synchronous motor Magnetic pole angle
Range: 0.0
–360.0
0.0
●
P17.30
Phase
compensation
of SM
Display synchronous motor phase compensation
Range: -180.0
–180.0
0.0
●
P17.31
High-frequency
superimposed
current of SM
Display
synchronous
motor
high-frequency
Superimposed current
Range: 0.0%
–200.0% (rated motor current)
0.0
●
P17.32
Magnetic flux
linkage
Display the magnetic flux linkage of the motor.
Range: 0.0%
–200.0%
0.0%
●
P17.33
Exciting
current
reference
Display the exciting current reference in the vector
control mode.
Range: -3000.0
–3000.0A
0.0A
●
P17.34
Torque current
reference
Display the torque current reference in the vector
control mode.
Range: -3000.0
–3000.0A
0.0A
●
P17.35
AC current
Display the value of inlet current in AC side.
Range: 0.0
–5000.0A
0.0A
●
P17.36 Output torque
Display the output torque. Positive value is in the
electromotion state, and negative is in the power
generating state.
Range: -3000.0Nm to 3000.0Nm
0.0Nm
●
P17.37
Count value of
motor
overload
0
–100 (100 reports OL1 fault)
0
●
P17.38
PID output
-100.00
–100.00%
0.00%
●
P17.39
Wrong
download of
parameters
0.00
–99.99
0.00
●