GD310-UL series VFD
Basic operation instruction
-141-
Function
code
Name
Description
Default
value
0: Setting is valid
1: Valid during running, cleared after stopping
2: Valid during running, cleared after
receiving the stop command
LED thousands:
∧
/
∨
keys and digital
potentiometer Integral function
0: The Integral function is valid
1: The Integral function is invalid
P08.43
Integral ratio of the
keypad potentiometer
0.01
–10.00s
0.10s
P08.44
UP/DOWN terminals
control
0x00
–0x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: All frequency means are valid
2: When the multi-step are priority, it is invalid
to the multi-step
LED hundreds: action selection when stop
0: Setting valid
1: Valid in the running, clear after stop
2: Valid in the running, clear after receiving
the stop commands
0x000
P08.45
UP terminals frequency
changing ratio
0.01
–50.00Hz/s
0.50 Hz/s
P08.46
DOWN terminals
frequency changing
ratio
0.01
–50.00 Hz/s
0.50 Hz/s
P17.00
Setting frequency
Display current set frequency of the VFD
Range: 0.00Hz
–P00.03
0.00Hz
P17.02
Ramp reference
frequency
Display current ramp given frequency of the
VFD
Range: 0.00Hz
–P00.03
0.00Hz
P17.14
Digital adjustment
Display the adjustment through the keypad of
the VFD.
Range : 0.00Hz
–P00.03
0.00V
Содержание GD310-011P-4-UL
Страница 1: ......
Страница 269: ...6 6 0 0 1 0 0 3 9 3 ...