Volume 1 / Print Engine - Error Codes & Messages
1
-
79
RAP 1-28
Error Code E5-1
Close Door A
The Left Door (A) is open.
The Left Door (A) is closed, but Logic Control on the Print Engine Controller Board
sensed the Left Door (A) Interlock Switch indicates the door is open
Table 1-56 Error Code E5-1 Close Door A
Step
Actions and Questions
Yes
No
1
LEFT DOOR CHECK
Open and close the Left Door (A).
Does the error code appear?
Tighten the
Switch
Bracket screw
(RRP 1-71)
Go to step 2
2
LEFT DOOR INTERLOCK SWITCH
INSPECTION
1. Remove the Rear Cover (RRP 1-5).
2. Inspect the Left Door (A) Interlock Switch for damage,
such as a broken or missing spring or a broken switch
button.
Is the switch undamaged?
Go to step 3
Replace the
Left Cover
Interlock
Switch (RRP
1-71)
3
LEFT DOOR INTERLOCK ACTUATOR
INSPECTION
Open and close the Left Door (A) while observing the
action of the Left Door (A) Actuator against the Interlock
Switch Spring.
Is the Left Cover Interlock Actuator pressing
against the Interlock Switch Spring?
Go to step 4
Replace the
Left Upper
Cover (RRP
1-42)
4
LEFT DOOR INTERLOCK SWITCH TEST
1. Enter Diagnostics Mode.
2. From the Main Menu, select Comp Input Test / IOT
Unit / L/H Cover A.
3. Press [4] to start, [0] to stop.
4. Actuate and deactuate the Left Door Interlock Switch.
Does the display indicate Open/Closed when
you actuate and deactuate the Left Cover
Interlock Switch?
Go to step 5
Replace the
Left Cover
Interlock
Switch (RRP
1-71)
5
PRINT ENGINE CONTROLLER BOARD
REPLACEMENT
Replace the Print Engine Controller Board (RRP 1-72.
Does the error code appear?
Go to step 6
Problem
solved
6
The following printer components and areas are
associated with this specific problem. One or more of
these components or areas may have failed partially or
completely. If you cannot isolate this problem using the
steps in this Repair Analysis Procedure, replace each
component or troubleshoot each area listed below, one at
a time, until you isolate and solve the problem.
Wiring and connectors linking the components
Input/Output Board (RRP 1-70).