1-168
DocuPrint N4525 Network Laser Printer - Service Guide
Press [2] or [6] to
display:
ß
Press [3] or [7] to
display:
ß
Action To Take
Displayed Result
Comp Input Test
HCF Unit
HCF Unit
HCF Cab. Cover C
1. Press [4] to begin test.
2. Open L/H Door C.
3. Press [0] to end test.
Close
Open
HCF Unit
Tray 3 Paper Sen
1. Remove Tray 3.
2. Press [4] to start test.
3. Manually actuate/deactuate
the Tray 3 No Paper Sensor
and observe display.
4. Press [0] to end test.
With Paper
Without Paper
HCF Unit
Tray 4 Paper Sen
1. Remove Tray 4.
2. Press [4] to start test.
3. Manually actuate/deactuate
the Tray 4 No Paper Sensor
and observe display.
4. Press [0] to end test.
With Paper
Without Paper
HCF Unit
Tray 5 Paper Sen
1. Remove Tray 5.
2. Press [4] to start test.
3. Manually actuate/deactuate
the Tray 5 No Paper Sensor
and observe display.
4. Press [0] to end test.
With Paper
Without Paper
HCF Unit
Tray 3 Level
1. Press [4] to begin test.
2. Pull Tray 3 part way out/push
in.
3. Press [0] to end test.
Down
Up
HCF Unit
Tray 4 Level
1. Press [4] to begin test.
2. Pull Tray 4 part way out/push
in.
3. Press [0] to end test.
Down
Up
HCF Unit
Tray 5 Level
1. Press [4] to begin test.
2. Pull Tray 5 part way out/push
in.
3. Press [0] to end test.
Down
Up
HCF Unit
T/A Roll3 Sensor
1. Press [4] to begin test.
2. Open L/H Door B/Place
paper over Take Away
Roller 3 Sensor.
3. Press [0] to end test
Without Paper
With Paper
HCF Unit
T/A Roll4 Sensor
1. Press [4] to begin test.
2. Open L/H Door C/Place
paper over Take Roller 4
Sensor.
3. Press [0] to end test.
Without Paper
With Paper
HCF Unit
T/A Roll5 Sensor
1. Press [4] to begin test.
2. Open L/H Door C/Slide
paper into Tray 5 exit
transport.
3. Press [0] to end test.
Without Paper
With Paper
Comp Input Test
Duplex Unit
Duplex Unit
Interlock
1. Press [4] to begin test.
2. Open Duplex Unit.
3. Press [0] to end test.
Close
Open
Duplex Unit
Exit Sensor
1. Press [4] to begin test.
2. Actuate Duplex Exit Sensor.
3. Press [0] to end test.
Without Paper
With Paper
Duplex Unit
Wait Sensor
1. Press [4] to begin test.
2. Open Duplex Unit/Actuate
Wait Sensor at bottom.
3. Press [0] to end test.
Without Paper
With Paper
Table 1-106 Component Control Input Tests
Press [1] or [5] until to display:
Main Menu
Comp Input Test (cont'd.)