![Xerox DocuPrint N4525 Service Quick Reference Manual Download Page 173](http://html.mh-extra.com/html/xerox/docuprint-n4525/docuprint-n4525_service-quick-reference-manual_885400173.webp)
Volume 1 / Print Engine - Diagnostics, Tests & NVRAM
1
-
151
Maintenance Reset Procedure
The Maintenance Kit is a user installable kit which replaces the paper feed rollers, bias
transfer roller, cleaning cloth, gloves and a fuser. The printer’s control panel display
informs the user when it is time to install a Maintenance Kit.
Upon completing the Maintenance Kit installation, it is necessary to reset the Maintenance
Kit Counter. Although wordless instructions are included with the kit, the procedure
below is provided for when those instructions are not available to you.
Note
The Maintenance Kit Counter should only be reset when a
complete kit has been installed.
Maintenance Kit Counter Reset Procedure
1.
Make certain the printer is OFF.
2.
Press and hold buttons [2] and [6] on the Control Panel while you switch ON
printer main power. Continue holding until
*
IOT?
*
appears in the display
(approximately 20 seconds).
3.
When the Control Display shows
*
IOT?
*
,
release buttons [2] and [6], then
press and hold button [0] and [5]. You have 10 seconds to release [2] and [6]
and press [0] and [5]. Hold [0] and [5] until “Reset Complete Please Reboot” is
displayed. This message confirms the counter has been reset.
4.
Reboot the printer by powering OFF, waiting 20 - 30 seconds and powering
ON.
The Maintenance Kit is a customer purchased / customer replaced unit (CRU). The
interval for replacement is 300K prints.
For Maintenance Kit part numbers, see Xerox Supplies and Accessories in the FRU Parts
Lists on page 1-338.