System parameter group 00
PARAMETER DESCRIPTION 78
5. PARAMETER DESCRIPTION
5.1 System parameter group 00
Group
Parameter
Number
Name
Setting Range
Default
Page
00-00
P.90
Inverter model
Read only
Read
only
00-01
P.188
Firmware version
Read only
Read
only
00-02
P.996~P.999 Parameter restoration
0: Off
0
1: Clear alarm history (P.996=1)
2: Reset inverter (P.997=1)
3: Restore all parameters to default (P.998=1)
4: Restore some parameters to default 1 (P.999=1)
5: Restore some parameters to default 2 (P.999=2)
6: Restore some parameters to default 3 (P.999=3)
00-03
P.77
Selection of parameters
write protection
0: Parameters can be written only when the motor
stops.
0
1: Parameters cannot be written.
2: Parameters can also be written when the motor is
running.
3: Parameters cannot be read when in password
protection.
00-04
P.294
Password parameter
0~65535
0
00-05
P.295
Password setup
2~65535
0
00-06
P.110
Keypad
monitor
selection
X0: When inverter starts, keypad enters monitor mode
automatically, screen displays output frequency.
1
X1: When inverter starts, screen displays target
frequency.
X2: When inverter starts, keypad enters monitor mode
automatically, screen displays current pressure and
feedback pressure of the constant pressure system in
percentage.
X5: When inverter starts, keypad enters monitor mode
automatically, screen displays current pressure and
feedback pressure of the constant pressure system.
0X:Boot screen monitors output frequency
1X:Boot screen is in target frequency setting mode
2X:Boot screen monitors output current
3X:Boot screen monitors output voltage
00-07
P.161
Multi-function display
0: Output AC voltage (V)
0
1: Voltage between (+/P) and (-/N) terminals. (V)
2: Inverter temperature rising accumulation rate (%)
3: Target pressure of the constant pressure system
(Unit set by 08-44(P.252))
4: Feedback pressure of the constant pressure system
(Unit set by 08-44(P.252))