System parameter group 00
PARAMETER DESCRIPTION 83
5.1.2 Parameter restoration
Set parameters back to default.
Parameter
Name
Default
Setting Range
Content
00-02
P.996
~
P.999
Parameter restoration
0
0
Off
1
Clear alarm history (P.996=1)
2
Reset inverter (P.997=1)
3
Restore all parameters to default (P.998=1)
4
Restore some parameters to default 1 (P.999=1)
5
Restore some parameters to default 2 (P.999=2)
6
Restore some parameters to default 3 (P.999=3)
Parameter restoration
1: When 00-02(P.996~P.999) is set to 1, screen will flash
, the alarm record will be erased after writing,
and 00-02 is reset to 0.
2: When 00-02(P.996~P.999) is set to 1, screen will flash
and inverter will be reset, then 00-02(P.996~
P.999) is reset to 0. After resetting the inverter, the accumulated values in “electronic thermal relay” and “IGBT
module thermal relay” will be set to zero.
3: When 00-02(P.996~P.999) is set to 3, screen will flash
, all the parameters will be restored to the
default values except the parameters in table 1 below. After parameters are restored, 00-02(P.996~P.999) is
reset to 0.
Exception
The parameters in table 1 below will not be restored to the default values:
Group
No.
Name
Group
No.
Name
00-00
P.90
Inverter model
06-55
P.751
E12
00-01
P.188
Firmware version
06-56
P.752
Output frequency during E1 alarm
00-23
P.186 Motor types selection
06-57
P.753
Output current during E1 alarm
00-24
P.189
50Hz/60Hz switch selection
06-58
P.754
Output voltage during E1 alarm
01-08
P.21
Acceleration/deceleration time increments
06-59
P.755
Temperature rising accumulation rate during E1
alarm
06-27
P.292
Total inverter operation time (minutes)
06-60
P.756
PN voltage during E1 alarm
06-28
P.293
Total inverter operation time (days)
06-61
P.757
Total inverter operation time during E1 alarm
06-29
P.296
Total inverter power on time (minutes)
06-62
P.758
Inverter operation status code during E1 alarm
06-30
P.297
Total inverter power on time (days)
06-63
P.759
E1 alarm date (years / months)
06-31
P.298 Output power (low 16 position)
06-64
P.760
E1 alarm date (days/hours)
06-32
P.299 Output power(high 16 position)
06-65
P.761
E1 alarm date (minutes / seconds)
06-44
P.740
E1
06-70
P.766
Output frequency during E2 alarm
06-45
P.741
E2
06-71
P.767
Output current during E2 alarm
06-46
P.742
E3
06-72
P.768
Output voltage during E2 alarm
06-47
P.743
E4
06-73
P.769
Temperature rising accumulation rate during E2
alarm
06-48
P.744
E5
06-74
P.770
PN voltage during E2 alarm
06-49
P.745
E6
06-75
P.771
Total inverter operation time during E2 alarm
06-50
P.746
E7
06-76
P.772
Inverter operation status code during E2 alarm
06-51
P.747
E8
06-77
P.773
E2 alarm date (years / months)
06-52
P.748
E9
06-78
P.774
E2 alarm date (days/hours)
06-53
P.749
E10
06-79
P.775
E2 alarm date (minutes / seconds)
06-54
P.750
E11
07-44
P.829 Version of EP301 communication card
Setting