Basic parameter group 01
PARAMETER DESCRIPTION 110
5.2.8 Output frequency filter time
This filter can reduce the impact when switching the frequency between high and low, and thus reduce the vibration
of machine.
Parameter
Name
Default Setting Range
Content
01-15
P.28
Output frequency filter
time
0ms
0~1000ms
---
Output frequency filter time
The filtering effect is better when the value of 01-15(P.28) is larger, but will also increase
the response delay.
If 01-15(P.28) is set to 0, the filtering function is off.
5.2.9 Frequency jump
To avoid resonance from a mechanical system, these parameters allow jumping through resonant frequencies .
Parameter
Name
Default Setting Range
Content
01-16
P.91
Frequency jump 1A
99999
0~650.00Hz
---
99999
Invalid.
01-17
P.92
Frequency jump 1B
99999
0~650.00Hz
---
99999
Invalid.
01-18
P.93
Frequency jump 2A
99999
0~650.00Hz
---
99999
Invalid.
01-19
P.94
Frequency jump 2B
99999
0~650.00Hz
---
99999
Invalid.
01-20
P.95
Frequency jump 3A
99999
0~650.00Hz
---
99999
Invalid.
01-21
P.96
Frequency jump 3B
99999
0~650.00Hz
---
99999
Invalid.
Frequency jump
To avoid system’s mechanical resonance frequency when running the motor, the inverter provides three sets of
jump frequencies: 01-16(P.91) and 01-17(P.92) (the first set), 01-18(P.93) and 01-19(P.94) (the second set),
01-20(P.95) and 01-21(P.96) (the third set).
01-16
(P.91)
01-17
(P.92)
01-18
(P.93)
01-19
(P.94)
01-20
(P.95)
01-21
(P.96)
Output
frequency
(Hz)
Set frequency
after
avoidance (Hz)
Setting
Setting