Appendix 1 Parameter table
APPENDIX 324
Parameter
Number
Group
Name
Setting Range
Default
Page
P.83
03-00
Terminal
STF
input
function
24: STF+RT+RM
0
25: STR+RT+RM
26: STF+RT+RL+RM
27: STR+RT+RL+RM
28: RUN(Inverter runs forward)
29: STF/STR(use with RUN signal, when ON,
motor runs reverse;when OFF, motor runs
forward)
30: RES(External reset function)
31: STOP(Use as three line control with RUN
signal and STF-STR signal)
32: REX(Extend multi-speed to 16 levels)
33: PO(In “external mode", run programmed
operation)
34: RES_E (External reset, valid only when alarm.)
35: MPO (In “external mode” run manual cycle
operation.)
36: TRI(Triangle wave function)
37: GP_BP (Automatic switch between inverter
and commercial power-supply.)
38: CS(Manual switch to commercial power
supply)
39: STF/STR +STOP (Use with RUN signal, when
ON, motor runs reverse, when OFF, motor stops
then runs forward.)
40: P_MRS (Stops inverter output immediately by
pulse signal input)
41: PWM set frequency(Note 1)
42: Reserved
43: RUN_EN (Enable digital input terminal
operation)
44: PID_OFF (Enable digital input terminal turning
off PID)
45: Second mode
46: Initial roll radius selection 1
47: Initial roll radius selection 2
48: Thickness selection 1
49: Thickness selection 2
50: Winding unwinding switch
51: Pre-drive command
52: Save torque value
53: Save torque value enable
54: Revs counting signal (note1)
55: Speed/Torque control
switch
56: Roll radius reset
57: High-speed pulse input function (note1)
58: Analog terminal 2-5 high priority
59: Analog terminal 3-5 high priority
60: Built-in PLC start/stop
61: SHOM (Homing enable)
62: ORGP (Set homing point)
63: Position/Speed control switch