Multi-speed parameter group 04
PARAMETER DESCRIPTION 164
RL
RH
RM
REX
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
(High speed)
speed1
(Medium
speed)
Speed 2
(Low speed)
Speed 3
Speed
4
Speed
5
Speed
6
Speed
8
Speed
10
speed
11
Speed
12
Speed
13
Speed
14
Speed
15
O
u
tp
u
t
fr
e
q
u
e
n
cy
Speed
9
Speed
7
Speed
0
Time
When one of parameters 04-03
(P.24)
~04-06(P.27) and 04-07(P.142)~04-14(P.149)
value is 99999, the target
frequency is determined by the speed of RL, RM and RH, which is shown as below (the priority of terminals is
RL>RM>RH):
Parameter
Target frequency
04-03
(P.24)=
99999
04-04
(P.25)=
99999
04-05
(P.26)=
99999
04-06
(P.27)=
99999
04-07
(P.142)
=99999
04-08
(P.143)
=99999
04-09
(P.144)
=99999
04-10
(P.145)
=99999
04-11
(P.146)
=99999
04-12
(P.147)
=99999
04-13
(P.148)
=99999
04-14
(P.149)=
99999
RL(04-02
(
P.6
)
)
○
○
○
○
○
○
○
○
RM(04-01
(
P.5
)
)
○
○
○
RH(04-00
(
P.4
)
)
○
For example, when 04-05(P.26)= 99999, the target frequency is determined by RM(the setting value of
04-01(P.5).
Note: 1. Multi-speed is only valid in “external mode”, “combination mode 2”or “combined mode 4”.
3.
RL, RM, RH and REX mentioned in this section are the function names of the “multi-function digital input
terminal”. (For example, when 03-03(P.80)=2, select the M0 terminal to perform the RL (function).Please refer
to03-00~03-09(P.80~P.84,P.86,P.126~P.128,P.550),03-25~03-30(P.551~P.556),03-33~03-38(P.559~P.564);
Please refer to section 3.7 for wiring.