Digital input/ output parameter group 03
PARAMETER DESCRIPTION 159
5.4.15 Digital input / output terminal monitor
Used to monitor the status of digital input / output terminal.
Parameter
Name
Default Setting Range
Content
03-59
P.585
Monitor inverter digital
input terminal state
Read
only
Read only
---
03-60
P.586
Monitor inverter and
Slot3 digital output
terminal state
Read
only
Read only
---
03-61
P.587
Monitor Slot2&3 digital
input terminal state
Read
only
Read only
---
03-62
P.588
Monitor Slot2 digital
output terminal state
Read
only
Read only
---
Digital input / output terminal state
For input terminal: 1 means signal is given, 0 means no signal.
For output terminal: 1 means signal is outputting, 0 means no output.
b0
STF
STR
M0
M1
M2
RES
M3
M4
M5
HDI
Each bit corresponded input terminal of 03-59
(P.585)
:
b1
b2
b3
b5
b6
b7
b8
b4
b9
0
0
0
0
0
0
b10
b11
b12
b13
b14
b15
Each bit corresponded output terminal of 03-60
(P.586)
:
SO1
SO2
ABC1
ABC2
A10
A11
A12
A13
A14
A15
A16
A17
SLOT3 expanded
digital output
b0
b1
b2
b3
b5
b6
b7
b8
b4
b9
0
0
0
0
b10
b11
b12
b13
b14
b15
M10
M11
M12
M13
M14
M15
M10
M11
M12
M13
M14
M15
SLTO2 expanded
digital input
SLOT3
expanded
digital input
b0
b1
b2
b3
b6
b7
b8
b4
b9
0
0
0
0
b10
b11
b12
b13
b14
b15
b5
Each bit corresponded input terminal of 03-61
(P.587)
:
A10
A11
A12
A13
A14
A16
A17
A15
SLOT2 expanded digital
output
b0
b1
b2
b3
b6
b7
b8
b4
b9
0
0
0
0
b10
b11
b12
b13
b14
b15
b5
Each bit corresponded output terminal of 03-62
(P.588)
:
0
0
0
0
Read