Appendix 1 Parameter table
APPENDIX 360
Group
Parameter
Number
Name
Setting Range
Default
Page
01-27
P.99
Output voltage 1 of middle
frequency
0~100.0%
10.0%
01-28
P.162
Middle frequency 2
0~650.00Hz
99999
99999: Off
01-29
P.163
Output voltage 2 of middle
frequency
0~100.0%
0.0%
01-30
P.164
Middle frequency 3
0~650.00Hz
99999
99999: Off
01-31
P.165
Output voltage 3 of middle
frequency
0~100.0%
0.0%
01-32
P.166
Middle frequency 4
0~650.00Hz
99999
99999: Off
01-33
P.167
Output voltage 4 of middle
frequency
0~100.0%
0.0%
01-34
P.168
Middle frequency 5
0~650.00Hz
99999
99999: Off
01-35
P.169
Output voltage 5 of middle
frequency
0~100.0%
0.0%
01-36
P.255
S curve time at the
beginning of acceleration
0~25.00s/0~250.0s
0.20s
01-37
P.256
S curve time at the end of
acceleration
0~25.00s/0~250.0s
99999
99999: Off
01-38
P.257
S curve time at the
beginning of deceleration
0~25.00s/0~250.0s
99999
99999: Off
01-39
P.258
S curve time at the end of
deceleration
0~25.00s/0~250.0s
99999
99999: Off
01-43
P.215
Second base voltage
0~1000.0V
99999
99999:Change according to the input voltage
02-00
P.500
Terminal 2-5 input function
0: Off
1
1: Frequency command
2: Torque command
3: PID target value
4: PID feedback signal
5: Tension target value
6: Line speed
7: Line speed feedback
8: Real-time roll diameter
9: Initial roll diameter
10: Material thickness
11: PTC thermistor
12: PT100 thermistor
13: VF separate function
14: Positive torque limit
15: Negative torque limit
16: Positive/Negative torque limit
17: Regenerative torque limit