Analog input and output parameter group 02
PARAMETER DESCRIPTION 120
5.3.1 Analog input terminals and HDI terminal function selection
Input function selection of terminal 1, 2, 3 and HDI
Parameter
Name
Default Setting Range
Content
02-00
P.500
Terminal 2-5 input
function
1
0
Off
1
Frequency command
2
Torque command
3
PID target value
4
PID feedback signal
5
Tension target value
6
Line speed
7
Line speed feedback
8
Real-time roll diameter
9
Initial roll diameter
10
Material thickness
11
PTC thermistor
12
PT100 thermistor
13
VF separate function
14
Positive torque limit
15
Negative torque limit
16
Positive/Negative torque limit
17
Regenerative torque limit
02-01
P.501
Terminal 4-5
input
function
1
Same as
02-00(P.500)
Same as 02-00(P.500)
02-02
P.504
Terminal 3-5 input
function
0
Same as
02-00(P.500)
Same as 02-00(P.500)
02-03
P.503
Terminal HDI input
function
0
Same as
02-00(P.500)
Same as 02-00(P.500)
Input function selection
When set to 1 frequency command, 0~±10V / 4~20mA corresponds to 0~ maximum output frequency.
Note: 1. The default priority level is 2-5 > 4-5 >3-5 > HDI, if set terminal 3-5 as frequency command, 02-00(P.500) and
02-01(P.501) should also be set to 0.
Setting