Basic operation steps for different modes
BASIC OPERATION 74
Step
Description
3
•
Press
FWD
or
REV
on PU301 keypad to run the motor. At this point, indicator in
FWD
or
REV
will
flash, indicating that the motor is running.
Note: 1. For detailed operation procedures for monitoring mode, please refer to section 4.2.3.
2.When the motor is running, the frequency can also be set. You can change the target frequency in
the memory to change the motor speed.
4
•
Press
RESET
STOP
and the motor will begin to decelerate until it comes to a full stop.
• Indicator in
FWD
or
REV
will NOT turn off until the inverter stops outputting
.
4.3.7 Basic operation steps for combined mode 3(00-16(P.79)=6)
Step
Description
1
• In Combined Mode 3, indicator in
PU
will flash.
Note: 1. For detailed operation procedures for monitor mode, please refer to section 4.2.
2
• The default priority is from high to low.
• When the external JOG is ON, the target frequency is determined by the value of 01-13(P.15), and the
acceleration/deceleration time is determined by the value of 01-14(P.16).
• When M0, M1, M2, REX multi-speed are ON, the target speed setting is determined by multi-speed
combination setting, please refer to section 5.5.1 Multi-speed 16.
• Performing target frequency setting by communication
3
•The inverter starting is activated by the external Run Forward or Run Reverse terminals. At this point,
indicating lamp
FWD
or
REV
will flash, indicating that the motor is running.
•Functions of 00-02(P.996~P.999) can be accomplished by communication.
Note: 1. For detailed operation procedures for monitoring mode, please refer to section 4.2.3.
4
•When the digital input terminals output stop signals, motor will decelerate until it comes to a full stop.
• Indicator in
FWD
or
REV
will not turn off until the inverter stops outputting.
4.3.8 Basic operation steps for combined mode 4(00-16(P.79)=7)
Step
Description
1
•In Combined Mode 4, indicator in
PU
will flash.
Note: 1. For detailed operation procedures for monitor mode, please refer to Section 4.2.
2
• The target frequency is set by external terminal (the default priority is from high to low)
• If the program operation mode is selected, refer to section 5.4.1 Digital Input Function Option and section
5.5.2 Program Operation Mode.
• If the target frequency is set by multi-speed, refer to section 5.5.1 Multi-speed 16.
• If the target frequency is set by A2/B2 terminal input signal setting of PG card, refer to section 5.10.4 PG2
Parameter.
• If the target frequency is set by PWM pulse input, please refer to section 5.4.1 Digital Input Function
Selection.
•If the target frequency is set by 2-5 terminal input signal, refer to section 5.3.5 2-5 Input Selection and
Processing.
•If the target frequency is set by 4-5 terminal input signal, refer to section 5.3.6 4-5 Input Selection and
Processing.
•If the target frequency is set by 3-5 terminal input signal, refer to section 5.3.7 4-5 Input Selection and
Processing.
•If the target frequency is set by HDI terminal high-speed pulse input, refer to section 5.3.8 HDI Input Selection
and Processing.