PG feedback parameter group 09
PARAMETER DESCRIPTION 237
Group
Parameter
Number
Name
Setting Range
Default
Page
09-11
P.360
Anti-reversal detection pulse
0~65535
0
09-12
P.361
Reversal detection frequency 0~65535
0
09-13
P.124
Expansion card version
Read only
Read
09-14
P.363
Z phase correction allowance
0.0°:Off
15.0°
0.1°~360.0°:Z phase pulse correction
09-15
P.364
Z phase DV1/DV2 alarm
enabled
0:Off
1
1:Z phase DV1/DV2 alarm valid
09-16
P.386
Encoder signal detection
setting
1 digit:PG302L hardware
disconnection check
0:Off
1
1:Valid
2 digit:A1/B1 phase sequence check
0:Off
1:Valid
09-17
P.416
Encoder mounting
transmission ratio
0~65.535
1.000