PG feedback parameter group 09
PARAMETER DESCRIPTION 243
5.10.9
PG card Z phase correction margin Z
Adjust phase Z to clear cumulative error of AB phase.
Parameter
Name
Default Setting Range
Content
09-14
P.363
Z phase correction
margin
15.0°
0.0°
No correction
0.1°~360.0°
Execute Z phase pulse correction
Z phase correction margin
Judge the pulse deviation value of the AB phase between to neighboring Z phase. Technically, the deviation
value=09-01(P.350) [or 4*09-01(P.350)] , convert into mechanical angle with 360 degrees. When subtracting
09-01 (P.350)[or 4*09-01(P.350)] from the deviation is lesser than 09-14(P.363), and the deviation is greater
than 09-04(P.353),execute Z phase correction.
When Z phase is disturbed by external factors, set 09-14(P. 363) to 0..
Note: Only valid when PM motor is in VC modem motor in position mode.
5.10.10 DV1/DV2 alarm of PG card Z phase
For selecting If Z phase DV1/DV2 alarm is enabled
Parameter
Name
Default Setting Range
Content
09-15
P.364
Z phase DV1/DV2
alarm
1
0
Z phase DV1/DV2 alarm disabled
1
Z phase DV1/DV2 alarm enabled
Enable DV1/DV2 alarm of phase Z
DV1 is the alarm when Z phase is lost,DV2 is the alarm when noise in Z phase is detected. When 05-15(P.364)
=0,DV1,DV2 can be canceled.
Note:
Only valid when 00-21(P.300)=5
5.10.11 Encoder Mounting transmission ratio
It is used to set the transmission ratio between the encoder mounting shaft and the motor shaft.
Parameter
Name
Default
Setting Range
Content
09-17
P.416
Encoder
mounting
transmission ratio
1.000
0~65.535
---
Encoder mounting transmission ratio
If the encoder is not installed on the motor shaft and the transmission ratio is not 1:1, this parameter shall be set.
The relation between parameters 09-17 (P.416) and mechanical installation is as follows: motor speed/encoder
installation shaft speed
Setting
Setting
Setting