PG feedback parameter group 09
PARAMETER DESCRIPTION 240
5.10.3 PG error detection
The definition of the standard of error detection when PG feedback control
Parameter
Name
Default Setting Range
Content
09-03
P.352
PG error detection
time
1.0s
0~100.0s
PG disconnect detection time setting
09-04
P.353
Over-speed detection
frequency
4.00Hz
0~30.00Hz
Motor Over-speed detection frequency setting
09-05
P.354
Over-speed detection
time
1.0s
0~100.0s
Motor Over-speed detection time setting
09-16
P.386
Encoder signal
detection setting
1
One digit:
0:PG302L hardware disconnect detection invalid
1:PG302L hardware disconnect detection valid
Two digit:
0:A1/B1 phase sequence detection invalid
1:A1/B1 phase sequence detection valid
PG error detection
When executing PG feedback control, if detected frequency is 0,and over the set time of 09-03(
P.352
),it should be
determined as error of PG card`s feed back signal. Inverter will display alarm PG2 and end operation. If PG signal
error(zero speed)detection time 09-03(
P.352
) is 0,then no PG card feedback signal error function,i.e.,no alarm
PG2.
When executing PG feedback control,if different between detected frequency and output frequency is over
09-04(
P.353
),and over the time set of 09-05(
P.354
),the speed deviation should be determined as too fast. Inverter
will display alarm PG3 and end operation. .If PG Over-speed detection time 09-05(P.354) is set to 0,then no alarm
PG3 function.
PG302Lhardware disconnection detection function (09-16(P.386) one-digit)effective to PM/IM motors,A1/B1
phase sequence detection function(09-16(P.386) two digits)only effective to IM motor
5.10.4 PG2 parameter
Used to select the input type of PG2 encoder
Parameter
Name
Default Setting Range
Content
09-06
P.355
Encoder pulse 2
2500
0~20000
Setting of A2/B2 encoder information connected to PG03.
09-07
P.356
Encoder input type 2
0
0
Off
1
A/Phase B pulse wave,forward spin when phase A is over
phase B for 90 degrees.
2
A/Phase B pulse wave,forward spin when phase B is over
phase A for 90 degrees.
3
Phase A :pulse wave,Phase B:directional sign,L:reverse
spin,H:forward spin
4
Phase A :pulse wave,Phase B: directional sign,L:forward
spin,H:reverse spin
Setting