System parameter group 00
PARAMETER DESCRIPTION 84
Group
No.
Name
Group
No.
Name
09-13
P.124 Expansion card version
13-03
P.286 High frequency vibration inhibition factor
13-02
P.285 Low frequency vibration inhibition factor
4: : When 00-02(P.996~P.999) is set to 4, screen will flash
, all the parameters will be restored to the
default values except the parameters in table 1 and table 2 below after writing. After parameters are restored,
00-02(P.996~P.999) is reset to 0.
Exception
The parameters in table 2 below and table 1 will not be restored to default values:
Group
No.
Name
Group
No.
Name
00-21
P.300
Motor control mode selection
02-47
P.190 Terminal AM1 output bias
02-12
P.192
Terminal 2-5 minimum input positive voltage
02-49
P.536 Terminal AM2 output gain
02-13
P.193
Terminal 2-5 maximum input positive voltage
02-50
P.535 Terminal AM2 output bias
02-14
P.194
Percentage corresponds to terminal 2-5
minimum positive voltage
02-59
P.187 FM calibration coefficient
05-00
P.301 Motor specifications automatic measurement
02-15
P.195
Percentage corresponds to terminal 2-5
maximum positive voltage
05-01
P.302 Motor rated power
02-16
P.512
Terminal 2-5 minimum input negative voltage
05-02
P.303 Motor poles
02-17
P.513
Terminal 2-5 maximum input negative voltage
05-03
P.304 Motor rated voltage
02-18
P.510
Percentage corresponds to terminal 2-5
minimum negative voltage
05-04
P.305 Motor rated frequency
05-05
P.306 Motor rated current
02-19
P.511
Percentage corresponds to terminal 2-5
maximum negative voltage
05-06
P.307 Motor rated rotation speed
05-07
P.308 Motor excitation current
02-25
P.198
Terminal 4-5 minimum input current/ voltage
05-08
P.309 IM motor stator resistance
02-26
P.199
Terminal 4-5 maximum input current/ voltage
05-09
P.310 IM motor rotor resistance
02-27
P.196
Percentage corresponds to terminal 4-5
minimum input current/ voltage
05-10
P.311 IM motor leakage inductance
05-11
P.312 IM motor mutual inductance
02-28
P.197
Percentage corresponds to terminal 4-5
maximum input current/ voltage
05-12
P.313 PM motor stator resistance
05-13
P.314 PM motor d-axis inductance
02-34
P.548
Terminal 3-5 minimum input current/ voltage
05-14
P.315 PM motor q-axis inductance
02-35
P.549
Terminal 3-5 maximum input current/ voltage
05-15
P.316 PM motor Back-EMF coefficient
02-36
P.546
Percentage corresponds to terminal 3-5
minimum input current/ voltage
05-16
P.317
PM motor Phase Z origin pulse
compensation
02-37
P.547
Percentage corresponds to terminal 3-5
maximum input current/ voltage
05-17
P.318 The motor inertia
05-18
P.319 Load inertia ratio
11-00
P.320 Speed control proportion coefficient 1
02-39
P.524
Terminal HDI minimum input frequency
11-01
P.321 Speed control integral time 1
02-40
P.525
Terminal HDI maximum input frequency
11-02
P.322 PI coefficient switching frequency 1
02-41
P.522
Percentage corresponds to terminal HDI
minimum input frequency
11-03
P.323 Speed control proportion coefficient 2
11-04
P.324 Speed control integral time 2
02-42
P.523
Percentage corresponds to terminal HDI
maximum input frequency
11-05
P.325 PI coefficient switching frequency 2
11-06
P.326 Current control proportion coefficient
02-46
P.191
Terminal AM1 output gain
5: User registered parameter 15-00(P.900)~15-19(P.919) and the parameters set in 15-00(P.900)~15-19(P.919)
and the parameters in table 1 above will not be restored to default values. After parameters are restored,
00-02(P.996~P.999) is reset to 0